{"id":14345,"date":"2021-01-12T17:30:15","date_gmt":"2021-01-12T16:30:15","guid":{"rendered":"http:\/\/www.cener.com\/en\/?page_id=14345"},"modified":"2022-02-07T12:14:48","modified_gmt":"2022-02-07T11:14:48","slug":"multi-wind-turbine-simulation-tool-must","status":"publish","type":"page","link":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/","title":{"rendered":"Multi wind turbine simulation tool (MUST)"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]MUST is an in-house development based on OpenFAST [1]. It is designed to allow the simulation of more than one wind turbine (Tower, Rotor, Nacelle) installed on a floating platform, following the work by [2].<\/p>\n<p>MUST has been coupled to a CENER in-house aerodynamic module, AeroVIEW [3], [4] (Aerodynamic Vortex fIlamEnt Wake), that is able to capture the aerodynamic interaction between nearby rotors in aeroelastic simulations and also the interaction between the rotor with its own wake.<\/p>\n<p><span style=\"font-size: 12px;\">[1] NREL, 2019. \u201c<a href=\"https:\/\/www.nrel.gov\/wind\/nwtc\/openfast.html\">OpenFAST Documentation<\/a>\u201d.<\/span><br \/>\n<span style=\"font-size: 12px;\">[2] Bae, Y., 2013. \u201c<a href=\"https:\/\/www.proquest.com\/openview\/c0002e2c78293371ae19c03f5847425c\/1?pq-origsite=gscholar&amp;cbl=18750\">Coupled dynamic analysis of multiple unit floating offshore wind turbine<\/a>\u201d. PhD. Dissertation, 53 (May).\u00a0<\/span><br \/>\n<span style=\"font-size: 12px;\">[3] Mart\u00edn-San-Rom\u00e1n R, Azcona-Armend\u00e1riz J and Cuerva-Tejero A. \u201c<a href=\"https:\/\/asmedigitalcollection.asme.org\/OMAE\/proceedings-abstract\/IOWTC2019\/59353\/V001T01A019\/1071993\">Lifting line free wake vortex filament method for the evaluation of floating offshore wind turbines. First step: validation for fixed wind turbines<\/a>\u201d. In IWOTC, ASME 2019 2nd International Offshore Wind Technical Conference.\u00a0\u00a0<\/span><br \/>\n<span style=\"font-size: 12px;\">[4] Mart\u00edn-San-Rom\u00e1n R, Benito-Cia P, Azcona-Armend\u00e1riz J and Cuerva-Tejero A.\u201c<a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0960148121011605\">Validation of a free vortex filament wake module for the integrated simulation of multi-rotor wind turbines<\/a>\u201d. Renewable Energy,179, pp. 1706\u20131718, 2021.<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtu.be\/rlc_ClNFAYI&#8221; el_width=&#8221;80&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;16px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]MUST is an in-house development based on OpenFAST [1]. It is designed to allow the simulation of more than one wind turbine (Tower, Rotor, Nacelle) installed on a floating platform, following the work by [2]. MUST has been coupled to a CENER in-house aerodynamic module, AeroVIEW [3], [4] (Aerodynamic Vortex fIlamEnt Wake), that is&hellip;<\/p>\n","protected":false},"author":1,"featured_media":505,"parent":555,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-14345","page","type-page","status-publish","has-post-thumbnail","hentry","entry","has-media"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]MUST is an in-house development based on OpenFAST [1]. It is designed to allow the simulation of more than one wind turbine (Tower, Rotor, Nacelle) installed on a floating platform, following the work by [2]. MUST has been coupled to a CENER in-house aerodynamic module, AeroVIEW [3], [4] (Aerodynamic Vortex fIlamEnt Wake), that is&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/\" \/>\n<meta property=\"og:site_name\" content=\"CENER - National Renewable Energy Centre\" \/>\n<meta property=\"article:modified_time\" content=\"2022-02-07T11:14:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2017\/07\/cab-eolica.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"970\" \/>\n\t<meta property=\"og:image:height\" content=\"229\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/\",\"url\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/\",\"name\":\"Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2017\\\/07\\\/cab-eolica.jpg\",\"datePublished\":\"2021-01-12T16:30:15+00:00\",\"dateModified\":\"2022-02-07T11:14:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2017\\\/07\\\/cab-eolica.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2017\\\/07\\\/cab-eolica.jpg\",\"width\":970,\"height\":229},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/multi-wind-turbine-simulation-tool-must\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cener.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wind Turbine Analysis and Design (ADA)\",\"item\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wind-turbine-analysis-design\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Multi wind turbine simulation tool (MUST)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.cener.com\\\/en\\\/\",\"name\":\"CENER - National Renewable Energy Centre\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cener.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#organization\",\"name\":\"CENER - National Renewable Energy Centre\",\"url\":\"https:\\\/\\\/www.cener.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2022\\\/01\\\/logo-cener-cabecera-english-2022.png\",\"contentUrl\":\"https:\\\/\\\/www.cener.com\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2022\\\/01\\\/logo-cener-cabecera-english-2022.png\",\"width\":1650,\"height\":250,\"caption\":\"CENER - National Renewable Energy Centre\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cener.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/","og_locale":"en_US","og_type":"article","og_title":"Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre","og_description":"[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]MUST is an in-house development based on OpenFAST [1]. It is designed to allow the simulation of more than one wind turbine (Tower, Rotor, Nacelle) installed on a floating platform, following the work by [2]. MUST has been coupled to a CENER in-house aerodynamic module, AeroVIEW [3], [4] (Aerodynamic Vortex fIlamEnt Wake), that is&hellip;","og_url":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/","og_site_name":"CENER - National Renewable Energy Centre","article_modified_time":"2022-02-07T11:14:48+00:00","og_image":[{"width":970,"height":229,"url":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2017\/07\/cab-eolica.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/","url":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/","name":"Multi wind turbine simulation tool (MUST) - CENER - National Renewable Energy Centre","isPartOf":{"@id":"https:\/\/www.cener.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/#primaryimage"},"image":{"@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2017\/07\/cab-eolica.jpg","datePublished":"2021-01-12T16:30:15+00:00","dateModified":"2022-02-07T11:14:48+00:00","breadcrumb":{"@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/#primaryimage","url":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2017\/07\/cab-eolica.jpg","contentUrl":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2017\/07\/cab-eolica.jpg","width":970,"height":229},{"@type":"BreadcrumbList","@id":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/multi-wind-turbine-simulation-tool-must\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cener.com\/en\/"},{"@type":"ListItem","position":2,"name":"Wind Turbine Analysis and Design (ADA)","item":"https:\/\/www.cener.com\/en\/wind-turbine-analysis-design\/"},{"@type":"ListItem","position":3,"name":"Multi wind turbine simulation tool (MUST)"}]},{"@type":"WebSite","@id":"https:\/\/www.cener.com\/en\/#website","url":"https:\/\/www.cener.com\/en\/","name":"CENER - National Renewable Energy Centre","description":"","publisher":{"@id":"https:\/\/www.cener.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cener.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.cener.com\/en\/#organization","name":"CENER - National Renewable Energy Centre","url":"https:\/\/www.cener.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cener.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2022\/01\/logo-cener-cabecera-english-2022.png","contentUrl":"https:\/\/www.cener.com\/en\/wp-content\/uploads\/sites\/2\/2022\/01\/logo-cener-cabecera-english-2022.png","width":1650,"height":250,"caption":"CENER - National Renewable Energy Centre"},"image":{"@id":"https:\/\/www.cener.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/pages\/14345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/comments?post=14345"}],"version-history":[{"count":6,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/pages\/14345\/revisions"}],"predecessor-version":[{"id":15376,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/pages\/14345\/revisions\/15376"}],"up":[{"embeddable":true,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/pages\/555"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/media\/505"}],"wp:attachment":[{"href":"https:\/\/www.cener.com\/en\/wp-json\/wp\/v2\/media?parent=14345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}